Why Choose Our Coslight Solar Battery in India?

This VRLA battery line is preferred across India for performance, life, and reliability in solar power systems.

Bank of Coslight 2V VRLA Solar Battery units installed in series.

Technical Specifications for Coslight GFM Series

Find the right 2V VRLA Solar Battery model for your system.

Key Features

  • 2V SMF Advanced VRLA for efficient power delivery.
  • High energy density—ideal for solar storage.
  • No acidic fumes—cleaner, safer installations.
  • Exceptional deep discharge recovery.
  • Low self-discharge for standby reliability.
  • Fast recharge capability to reduce downtime.
  • Maintenance-free SMF—fit and forget.

Significant Benefits

  • Superb charge acceptance.
  • Consistent power output & long cycle life.
  • Direct factory dispatch for freshness.
  • Pan-India on-site support by COSLIGHT.
  • Resilient to hot & harsh Indian climates.

Robust Construction

  • Proprietary alloy grids (positive & negative).
  • High-purity lead oxide plates.
  • Premium micro-porous AGM separators.
  • Flame retardant UL94-V0 container.
  • Brass inserts on front terminal models.
  • One-way pressure relief valves.
  • Flame arrestor in each cell.
Coslight 600 AH 2V VRLA Solar Battery close-up.

Quality Standards & Operation

Built to international standards for reliable, long-term operation in Solar Battery systems.

Certifications & Standards

  • Complies with IS 15549:2005 and IEC 60896-21/22.
  • Manufacturing units: ISO 9001:2015, ISO 14001:2015, ISO 45001:2018.

Installation & Performance

  • Space-efficient footprint for easy installation.
  • VRLA design for zero maintenance.
  • >10-year life expectancy in float service at 25°C.
  • Wide operating temperature: discharge −15°C to 50°C.

GENERAL SPECIFICATION

2V VRLA – GFM Series (dimensions in millimetres; weights approximate)

Coslight GFM Models – Capacity, Dimensions, Weight & Terminals
Model Nominal Capacity
(Ah @ 27 °C)
Nominal Voltage
(V)
L
(mm) ±3
W
(mm) ±3
H
(mm) ±3
Approx. Weight
(kg) ±3%
Terminal Type Plastic
GFM-100100280.7173.0268.07.2M6ABS
GFM-120120280.7173.0268.07.9M6ABS
GFM-150150284.0173.0268.08.5M6ABS
GFM-180180292.3177.6372.011.7M8ABS
GFM-200200292.3177.6372.013.1M8ABS
GFM-3003002135.0178.5372.018.3M8ABS
GFM-4004002164.0179.5373.024.1M8ABS
GFM-5005002206.7180.0373.029.5M8ABS
GFM-6006002235.5180.5373.035.0M8ABS
GFM-8008002318.0179.4382.045.0M8ABS
GFM-100010002419.6181.6382.060.0M8ABS

Tip: On smaller screens, scroll the table horizontally .

Tolerances ±3 mm (dimensions) and ±3% (weight).

Constant Current Discharge (Ampere at 25 °C)

End voltage vs. constant-current discharge capability. Values are in ampere (A).
End Voltage Minute Hour
5 10 15 30 40 50 1 2 3 4 5 8 10
1.85 V 1.861.601.050.710.610.54 0.500.320.240.190.160.110.09
1.80 V 2.001.681.260.790.670.57 0.520.320.250.200.160.120.10
1.75 V 2.121.781.400.810.690.60 0.550.330.260.210.170.120.10
Tip: swipe/scroll horizontally on small screens.

Note: Values are discharge currents in amperes (A) at 25 °C. “End Voltage” refers to the per-cell cut-off voltage of a lead-acid battery (e.g., 1.85 V/cell).